![]() ![]() The Safest Way to Test Electrical Devices and Identify Electric Wires! Licensed Electrician Reveals the Secrets of Successful Electrical Troubleshooting Methods used to solve the majority of the home electrical problems and wiring failures encountered.Įlectrical Wiring Projects Electrical Code SearchĮlectrical Tips To Help You Wire it Right Using Electrical Testers and Voltage Meters Electrical testers and voltage meters enable you to identify electrical circuits and help prevent the possibility of accidental electrical shock. ![]() When working on home electrical wiring using voltage meter can play an important part in electrical safety. When properly installed, your home electrical wiring is protected by a circuit protection device. This article looks at common 120 volt and 240 volt house wiring circuits and the circuit breakers that are installed identifying the types and amperage sizes used in most homes.Ī guide to home electrical circuit breakers and how they work to protect your electrical wiring. More about Electrical Wiring and Circuit Breakers This is best tested and repaired by a qualified licensed electrician who will make the necessary repairs and then test the required GFCI protection as needed for the pool equipment. The problem may be due to a direct buried cable that has a direct short to ground, or it may be due to a problem with a connection at one of the electrical enclosures. All of the circuit wiring and connections will require testing to identify the fault and then the necessary repairs will be required.If the 30 amp circuit trips off again then I would suspect that there is a problem with the 30 amp circuit leading from the electrical panel to the pool equipment. If the 30 amp circuit does not trip off then there is a problem with the pool equipment. Dave, to determine the cause of this problem all of the pool equipment should be turned off or disconnected so that the 30 amp circuit can be tested.Notice: Repairs to Home Electrical Wiring should be done according to local and national electrical codes and installing new or replacement electrical parts or equipment may require a permit and inspections. Precaution: This is a project that should be performed by a Licensed Electrical Contractor and typically requires specific tests of the electrical circuits. Tools Required: Basic Electricians Pouch Hand Tools, Voltage Tester or Volt Ohm Meter.Įstimated Time: Depends on the type and age of the electrical wiring and the access to the circuits and wiring to be evaluated. This electrical wiring project is best performed by a Licensed Electrical Contractor or Certified Electrician. Thanks for your electrical question Dave Loss of Electrical Circuit Power to Pool EquipmentĪpplication: Troubleshooting Circuit Power to Pool Equipment. This electrical question came from: Dave, a Handyman from Tempe, Arizona My question is, what on earth would cause this cascading loss of power from a single breaker being tripped? Do I have a bigger problem than either a faulty breaker or faulty power lines for the pool? ![]() I however have left the 30-amp pool breaker off.I turned off the main breaker and waited about two minutes, then flipped it back on and everything came back to life, and has been working ok for the rest of the day so far knock on wood. I first tried to reset the 30-amp pool breaker, that did nothing. I ran to the main circuit board and noticed that the little wheel on the main meter was turning very, very slowly.Slowly, lights and appliances in other parts of the house, on different breakers, began to dim and eventually just went dead (a cascading effect). The lights in one of my bathrooms dimmed to about half, as well as the lights in the adjoining bedroom.A strange thing happened when the 30-amp breaker tripped the second time. Now it sounds like I might have an issue in the wiring between my main board and the pool board, but that is not my question.About 20 minutes later the 30-amp breaker tripped again. I reset the 30-amp and turned on the pool pump motor. ![]() This morning I found the 30-amp breaker had tripped, but neither of the two 15 amp breakers for the two pool motors. Power to this circuit board is run through a dedicated 30-amp double pole breaker on my main house circuit board.The power to these two motors is each routed through a 15 amp double-pole circuit breaker on a circuit board by the pool equipment. I have a built-in pool that has two motors, one for the in-pool cleaning system, and one for the filter.Testing and Identifying a Pool Equipment Circuit ProblemĮlectrical Question: What would cause the loss of power to my pool equipment? ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |